Deploy the IDS 9380 sensor

Intrusion Detection System (IDS) sensors integrate with packet sensors to generate detections based on industry-standard IDS signatures. This guide explains how to install the rack-mounted IDS 9380 sensor.

Installation prerequisites

To install the sensor, your environment must meet the following requirements:
Sensor
1U of rack space and electrical connections for 2 x 800W power supply units (PSUs).
Management
One 10/100/1000 BASE-T network port or one 10G BASE-SR port for sensor management.
Monitoring (capture)
High performance interfaces: One to six network ports for connection to 25 GbE or 10 GbE sources of packet data.
Management + monitoring interfaces: One to two network ports for connection to 1 GbE sources of packet data.
Network Access
Ensure that administrators can access the Administration settings on the sensor over TCP port 443.
Configure your firewall rules to allow outbound access over port 443 to ExtraHop Cloud Services.

For more information about the interfaces on the ExtraHop system, see the ExtraHop Hardware FAQ.

Rear panel ports

IDS 9380

  1. Power supply unit (PSU1) to connect the sensor to an AC power source
  2. Two 25 GbE-capable ports on two network adapters
  3. One RS-232 serial port to connect a console device
  4. Power supply unit (PSU2) to connect the sensor to an AC power source
  5. One VGA port to connect an external display
  6. Two USB 3.0 ports to connect input devices such as a keyboard and mouse
  7. One iDRAC interface port
  8. Two 10 GbE ports. These ports can be configured as a management port or management and RPCAP/ERSPAN/VXLAN/GENEVE target. These ports also function as high-performance monitoring (or capture) interfaces.
    Note:Processing RPCAP, ERSPAN, VXLAN, and GENEVE traffic is limited to 1 Gbps per interface in "Management + RPCAP/ERSPAN/VXLAN/GENEVE" modes, but the ports support up to 10 Gbps per interface in Monitoring and High-Performance ERSPAN/VXLAN/GENEVE target modes.
  9. Two 10/100/1000 BASE-T network ports. Port 1 is the default management port. These ports can be configured as a management port or management and RPCAP/ERSPAN/VXLAN/GENEVE target.
    Tip:In environments with asymmetric routing adjacent to the high-performance interfaces, ping replies might not get back to the sender.

Supported packet source connectivity

The sensor accepts packets through ports 1 to 8. Connect the ports according to the table below.
Connector Peer Connector for Packet Source Customer-Supplied Cabling Supported Operating Speeds
Transceiver-based Connectivity
25 GbE SFP28 SR transceiver 25 GbE SFP28 SR transceiver Multi-mode fiber

LC connectors

25 Gbps, 10 Gbps
10 GbE SFP+ SR transceiver Multi-mode fiber

LC connectors

10 Gbps
10 GbE SFP+ SR transceiver 10 GbE SFP+ SR transceiver Multi-mode fiber

LC connectors

10 Gbps
10 GbE SFP+ SR transceiver 10 GbE SFP+ SR transceiver Multi-mode fiber

LC connectors

10 Gbps
Direct Attach Connectivity
Customer-supplied SFP28 DAC cable, such as the Mellanox MCP2M00-Axxx series 25 Gbps
Customer-supplied RJ45 Ethernet cable 1 Gbps

Traffic distribution guidelines

  • Packets from the same flow should be received on the same interface, or on interfaces of the same network interface card (NIC).
  • The ingest on each NIC should not exceed 75% of the rated analysis throughput for the sensor to ensure that traffic is balanced across system resources.
  • If your data feed does not require both interfaces on the NIC, disable the unconfigured interfaces in the Administration settings. For example, configure the sensor with a single interface to ingest 50 Gbps on each NIC. Disable the extraneous ports on each NIC. This configuration optimizes performance for 100 Gbps.
  • A single high-performance ERSPAN target is expected to process 20 to 30 Gbps. On larger sensors, distribute ERSPAN traffic to more interfaces to scale traffic ingest.

Set up the sensor

  1. Rack mount the sensor.
    Install the sensor in your data center with the included rack-mounting kit. The mounting kit supports most four-post racks with either round or square holes.

    Orient the hardware to ensure proper airflow. The cold air intake is through the front of the sensor.

  2. Connect port 1 to your management network.
    This sensor has four 10/100/1000 BASE-T network ports. With a network patch cable, connect the management port on the sensor to your management network. Port 1 is the default management port.
  3. Connect the monitoring port.
    With the appropriate network cable, connect a monitoring port on the sensor to a network tap or mirror port on the switch.
    Important:To ensure the best performance for initial device synchronization, connect all sensors to the console and then configure network traffic forwarding to the sensors.
    Important:The IDS sensor requires a duplicate feed of the traffic that is sent to the packet sensor.
    Note:The link lights on the monitoring interface ports do not illuminate until you register the ExtraHop sensor, recordstore, or packetstore with your product key.
  4. (Optional): Connect the iDRAC port.
    To enable remote management of the sensor, connect your management network to the iDRAC port with a network patch cable.
  5. Install the front bezel.
    You must install the front bezel if you want to configure the sensor through the LCD display.

    Insert the USB connector on the right side of the bezel into the USB port on the front of the sensor. Press and hold the release button on the left end of the bezel and push the bezel flush with the sensor until it snaps into place.

  6. Connect the power cords.
    Connect the two supplied power cords to the power supply units (PSUs) on the back of the sensor, and then plug the cords into a power outlet. If the sensor does not power on automatically, press the power button on the front-right of the sensor.

Management IP address configuration

DHCP is enabled by default on the ExtraHop system. When you power on the system, the primary management interface attempts to acquire an IP address through DHCP. If successful, the IP address appears on the home screen of the LCD.

If your network does not support DHCP, you can configure a static IP address through the LCD menu on the front panel or through the command-line interface (CLI).

Important:We strongly recommend configuring a unique hostname. If the system IP address changes, the ExtraHop console can re-establish connection easily to the system by hostname.

Configure a static IP address through the LCD

Complete the following steps to manually configure an IP address through the front panel LCD controls.
  1. Make sure that the primary management interface is connected to the network and the link status is active.
  2. Press the select button (✓) to begin.
  3. Press the down arrow button to select Network, and then press the select button.
  4. Press the down arrow to select Set static IP, and then press the select button.
  5. Press the left or right arrows to select the first digit to change, and then press the up or down arrows to change the digit to the desired number.
    Repeat this step for each digit you need to change. After you configure the desired IP address, press the select button.
  6. On the Network mask screen, press the left or right arrows to select the first digit to change, and then press the up or down arrows to change the digit to the desired number.
    Repeat this step for each digit you need to change. After you configure the desired network mask, press the select button.
  7. On the Default gateway screen, press the left or right arrows to select the first digit to change, and then press the up or down arrows to change the digit to the desired number.
    Repeat this step for each digit you need to change. After you configure the desired default gateway, press the select button.
  8. Confirm your modified network settings on the Settings saved screen, and then press any button to return to the Network Menu.
    Note:Each address is preceded by a letter that identifies whether it is the system IP address (I), the gateway address (G), or the netmask (N).
  9. Press the down arrow and scroll to Set DNS servers, and then press the select button.
  10. Press the left or right arrows on the DNS1 screen to select the first digit to change, and then press the up or down arrows to change the digit to the desired number.
    Repeat this step for each digit you need to change, and then press the select button to continue to the DNS2 screen.
  11. Configure a second DNS server.
  12. Confirm the DNS settings on the Settings saved screen, and then press any button to return to the Network Menu.
  13. Press the down arrow twice until ← Back appears, and then press the select button.
  14. Press the down arrow twice to select iDRAC.
  15. Configure the iDRAC DHCP, IP, mask, gateway, and DNS in the same manner as the IP address.
  16. Press the X button to return to the main menu.

Configure an IP address through the CLI

Before you begin

You can access the CLI by connecting a USB keyboard and SVGA monitor to the appliance or through an RS-232 serial (null modem) cable and a terminal emulator program. Set the terminal emulator to 115200 baud with 8 data bits, no parity, 1 stop bit (8N1), and hardware flow control disabled.

You can manually configure an IP address from the CLI.

  1. Establish a connection to the ExtraHop system.
  2. At the login prompt, type shell and then press ENTER.
  3. At the password prompt, type the system serial number and then press ENTER.
    The serial number is printed on a label on the back of the unit. The serial number can also be found on the LCD display on the front of the unit in the Info section.
  4. Enable privileged commands:
    enable
  5. At the password prompt, type the serial number, and then press ENTER.
  6. Enter configuration mode:
    configure
  7. Enter interface configuration mode:
    interface
  8. Run the ip command and specify the IP address and DNS settings in the following format:
    ip ipaddr <ip_address> <netmask> <gateway> <dns_server>
    For example:
    ip ipaddr 10.10.2.14 255.255.0.0 10.10.1.253 10.10.1.254
  9. Leave configuration mode:
    exit
  10. Save the running configuration file:
    running_config save
  11. Type y and then press ENTER.
    Note:The system updates the running configuration file and applies the new settings when a link is detected on the interface.

(Optional) Configure the 10 GbE management interface

You can configure a 10 GbE port (port 1 or port 2) to manage the system. The commands below move the settings from port 3 to port 1 and then disables port 3. Alternatively, you can configure the 10 GbE management interface in the Administration settings.

The commands below demonstrate moving the settings from port 3 to port 1, and then disabling port 3. Alternatively, you can configure the 10 GbE management interface in the Administration settings.
  1. Make sure that port 1 is connected to the 10 GbE network.
  2. Establish an SSH connection to the ExtraHop system.
  3. At the login prompt, type shell and then press ENTER.
  4. At the password prompt, type the system serial number and then press ENTER.
    The serial number is printed on a label on the back of the appliance. The serial number is also on the LCD display on the front of the appliance in the Info section.
  5. Enable privileged commands:
    enable
  6. At the password prompt, type the serial number, and then press ENTER.
  7. Enter configuration mode:
    configure
  8. Enter interface configuration mode:
    interface 3
  9. Move the interface settings:
    Warning:This command overwrites the settings for Interface 1 with the settings from Interface 3. The current settings for Interface 1 will be lost and Interface 3 will be disabled.
    take_settings 1
  10. Type Y to proceed and then press ENTER.

Configure the IDS sensor

Perform the following procedures to configure the IDS sensor.
  1. Register your ExtraHop system.
  2. Connect to ExtraHop Cloud Services.
  3. Connect your ExtraHop console to the sensor.
  4. Join the IDS sensor to a site.
    Option Description
    For RevealX Enterprise
    1. Log in to the Administration settings on the console through https://<extrahop-hostname-or-IP-address>/admin.
    2. In the Connected Appliance Administration section, click Manage Sensors.
    3. On the Manage Connected Appliances page, click Actions next to the IDS sensor, and from the Appliance Actions drop-down list, click Join Site.
    4. From the Associated Site drop-down list, click the name of the site you want to join. You must join a site that has the same network feed as the IDS sensor.
    5. Click Join Site.
    For RevealX 360
    1. Log in to the Administration settings on the RevealX 360 system through https://<extrahop-hostname-or-IP-address>/console.
    2. In the left pane, click Sensors.
    3. Select the checkbox next to the name of the IDS sensor.
    4. On the Sensor Details pane, from the Associated Site drop-down list, select the name of the site you want to join. You must join a site that has the same network feed as the IDS sensor.
    5. Click Join Site.
  5. (Optional): Select the IDS Detections Tuning Parameters to enable detections for inbound traffic from external endpoints.
    By default, the ExtraHop system generates detections only for internal traffic.

Next steps

Complete the recommended procedures in the post-deployment checklist.
Last modified 2024-10-07