View Table of Contents
Hide Table of Contents
Product Requirements
- Reveal(x) 360 or ECA VM
Thank you! We will contact you soon to ask how we can improve our documentation. We appreciate your feedback.
Was this topic helpful?
How can we improve?
*This field is required. Please let us know how we can provide you with better help.
Need more help?
Ask the Community
Manage shared system settings
From a console, you can centrally manage shared system settings from each connected sensor for analysis priorities, records, trusted domains, and tuning parameters. You must specify the managing system from each sensor. Network Localities are centrally managed from ExtraHop Reveal(x) 360.
Important: | Management for Analysis Priorities, Collective Threat Analysis, Records, Trusted Domains, and Tuning Parameters are linked— if you transfer management for one setting, management is transferred for all of them. |
-
Log in to the ExtraHop system.
Repeat these steps on each sensor in your environment.
- Click the System Settings icon and then select Analysis Priorities, Tuning Parameters, or Record Collection.
- Click Transfer Management.
- Select the console.
- Click Transfer.
On a console only, you can configure central
management for third-party or cloud-based recordstore settings. From each sensor,
you must specify the managing console or whether the sensor is
self-managed.
- Log in to the Administration settings on the sensor.
- In the Records section, click Recordstore.
- Select the console from the drop-down list.
-
Click Transfer Ownership.
Note: The console does not display a list of connected sensors that share these settings.
Thank you for your feedback. Can we contact you to ask follow up questions?