Deploy the EDA 4200 or 6200 sensor

This guide explains how to install the rack-mounted EDA 4200 and EDA 6200 sensors.

Installation prerequisites

To install the sensor, your environment must meet the following requirements:
Appliance
1U of rack space and electrical connections for 2 x 495 W power supplies.
Management
One 10/100/1000 BASE-T network port for sensor management.
Monitoring (capture)
High performance interfaces: One to two network ports for connection to 10 GbE sources of packet data.
Management + monitoring interfaces: One to three network ports for connection to 1 GbE sources of packet data.
Network Access
Ensure that administrators can access the Administration settings on the sensor over TCP port 443.

For more information about the interfaces on the ExtraHop system, see the ExtraHop Hardware FAQ.

Rear panel ports

EDA 4200 and EDA 6200

  • One iDRAC interface port
  • One RS-232 serial port to connect a console device
  • One VGA port to connect an external display
  • Two USB 3.0 ports to connect input devices such as a keyboard and mouse
  • Two power ports to connect the appliance to an AC power source
  • Four 10/100/1000 BASE-T network ports. Port 1 is the primary management port. Ports 2 - 4 are the management + monitor ports.
  • Two 10 GbE-capable ports on one network adapter. Ports 5 and 6 are the high performance monitoring (capture) interfaces.
    Note:The EDA 4200 is only capable of data feed capture speeds of 5 Gbps or slower.

Supported packet source connectivity

The EDA 4200 and EDA 6200 can accept packets through monitoring ports 2 through 6. The ports can be connected according to the tables below.
Connector Peer Connector for Packet Source Customer-Supplied Cabling Supported Operating Speeds
Transceiver-based Connectivity
10 GbE SFP+ SR transceiver 10 GbE SFP+ SR transceiver Multi-mode fiber

LC connectors

10 Gbps
Direct Attach Connectivity
Customer-supplied SFP+ DAC cable, such as the Mellanox MC3309130-xxx series. 10 Gbps
Customer-supplied RJ45 Ethernet cable. 1 Gbps

Set up the sensor

  1. Rack mount the sensor.
    Install the sensor in your data center with the included rack-mounting kit. The mounting kit supports most four-post racks with either round or square holes.

    Orient the hardware to ensure proper airflow. The cold air intake is through the front of the sensor.

  2. Connect port 1 to your management network.
    The EDA 4200 and EDA 6200 sensors have four 10/100/1000 BASE-T network ports. With a network patch cable, connect the management port on the sensor to your management network. Port 1 is the default management port.
  3. Connect the monitoring port.
    Important:To ensure the best performance for initial device synchronization, connect all sensors to the console and then configure network traffic forwarding to the sensors.
    With the appropriate network cable, connect a monitor port on the sensor to a network tap or mirror port on the switch.
    Note:The link lights on the monitoring interface ports do not illuminate until you register the ExtraHop sensor, recordstore, or packetstore with your product key.
  4. (Optional): Connect the iDRAC port.
    To enable remote management of the sensor, connect your management network to the iDRAC port with a network patch cable.
  5. Install the front bezel.
    You must install the front bezel if you want to configure the sensor through the LCD display.

    Insert the USB connector on the right side of the bezel into the USB port on the front of the sensor. Press and hold the release button on the left end of the bezel and push the bezel flush with the sensor until it snaps into place.

  6. Connect the power cords.
    Connect the two supplied power cords to the power supplies on the back of the sensor, and then plug the cords into a power outlet. If the sensor does not power on automatically, press the power button on the front-right of the sensor.

Configure the management IP address

DHCP is enabled by default on the ExtraHop system. When you power on the system, interface 1 attempts to acquire an IP address through DHCP. If successful, the IP address appears on the home screen of the LCD.

If your network does not support DHCP, you can configure a static IP address through the LCD menu on the front panel or through the command-line interface (CLI).

Important:We strongly recommend configuring a unique hostname. If the IP address on the sensor is changed, the console can re-establish connection easily to the sensor by hostname.

Configure a static IP address through the LCD

Complete the following steps to manually configure an IP address through the front bezel LCD controls.
  1. Make sure that the default management interface is connected to the network and the link status is active.
  2. Press the select button (✓) to begin.
  3. Press the down arrow button to select Network, and then press the select button.
  4. Press the down arrow to select Set static IP, and then press the select button.
  5. Press the left or right arrows to select the first digit to change, and then press the up or down arrows to change the digit to the desired number. Repeat this step for each digit you need to change. After you configure the desired IP address, press the select button.
  6. On the Network mask screen, press the left or right arrows to select the first digit to change, and then press the up or down arrows to change the digit to the desired number. Repeat this step for each digit you need to change. After you configure the desired network mask, press the select button.
  7. On the Default gateway screen, press the left or right arrows to select the first digit to change, and then press the up or down arrows to change the digit to the desired number. Repeat this step for each digit you need to change. After you configure the desired default gateway, press the select button.
  8. Confirm your modified network settings on the Settings saved screen, and then press any button to return to the Network Menu.
  9. Press the down arrow and scroll to Set DNS servers, and then press the select button.
  10. Press the left or right arrows on the DNS1 screen to select the first digit to change, and then press the up or down arrows to change the digit to the desired number. Repeat this step for each digit you need to change, and then press the select button to continue to the DNS2 screen.
  11. Configure a second DNS server.
  12. Confirm the DNS settings on the Settings saved screen, and then press any button to return to the Network Menu.
  13. Press the down arrow twice until ← Back appears, and then press the select button.
  14. Press the down arrow twice to select iDRAC. Configure the iDRAC DHCP, IP, mask, gateway, and DNS in the same manner as the IP address.
  15. Press the X button to return to the main menu.

Configure an IP address through the CLI

You can access the CLI by connecting a USB keyboard and SVGA monitor to the appliance or through an RS-232 serial (null modem) cable and a terminal emulator program. Set the terminal emulator to 115200 baud with 8 data bits, no parity, 1 stop bit (8N1), and hardware flow control disabled.

  1. Establish a connection to the ExtraHop system.
  2. At the login prompt, type shell and then press ENTER.
  3. At the password prompt, type the system serial number and then press ENTER. The serial number is printed on a label on the back of the appliance. The serial number can also be found on the LCD display on the front of the appliance in the Info section.
  4. Enable privileged commands:
    enable
  5. At the password prompt, type the serial number, and then press ENTER.
  6. Enter configuration mode:
    configure
  7. Enter the interface configuration mode:
    interface
  8. Run the ip command and specify the IP address and DNS settings in the following format: ip ipaddr <ip_address> <netmask> <gateway> <dns_server>
    For example:
    ip ipaddr 10.10.2.14 255.255.0.0 10.10.1.253 10.10.1.254
  9. Leave the interface configuration section:
    exit
  10. Save the running config file:
    running_config save
  11. Type y and then press ENTER.

Configure the sensor

After you configure an IP address for the sensor, open a web browser and navigate to the ExtraHop system through the configured IP address. Accept the license agreement and then log in with the setup user account. The password is the system serial number that appears in the Info section of the LCD display and on the label on the back of the sensor. Follow the prompts to enter the product key, change the default setup and shell user account passwords, connect to ExtraHop Cloud Services, and connect to a console.

After the system is licensed, and you have verified that traffic is detected, complete the recommended procedures in the post-deployment checklist.